Laboratory Test Information Guide

Details for Vitamin A,Serum/Plasma

Test Name: Vitamin A,Serum/Plasma
Alternate Name(s):  
Laboratory: Toxicology/Special Chemistry
Specimen Type: Serum:

6 mL Red top Vacutainer tube

Plasma:

4 mL Lavender or 4.5 mL Green (Lithium Heparin) top Vacutainer tube
Collection Information: Fasting sample is recommended.

Minimum volume of serum or plasma required is 1 mL.

Spin and aliquot serum or plasma and freeze immediately and send to the lab.

Sample should be collected aseptically in a Vacutainer tube not containing separator gel.

Protect sample from light by wrapping in foil.
Requisition: GENERAL LABORATORY REQUISITION
Test Schedule: Once a week
Turnaround time from when specimen
is received in testing laboratory:
 
Routine
10 days
Stat
 
 
Reference Range: 0-<1 year: 0.4-2.3 Ámol/L
1-<12 years: 0.8-1.9 Ámol/L
12-<20 years: 1.0-2.6 Ámol/L
20-<40 years: 1.1-3.1 Ámol/L
40-<60 years: 1.2-3.5 Ámol/L
≥60 years: 1.3-3.8 Ámol/L
Effective Date: 2009-07-02
Revised Date: 2021-03-22
Critical Value:  
Interpretive Comments: Please note: new reference intervals as of March 22, 2021.
Special Processing: Protect sample from light and freeze immediately after separation.
Comments:  
Method of Analysis: HPLC/MS/MS
Critical Information Required:  
Storage & Shipment: Separate and freeze.
System Codes: 
Cerner
VITA
 
Referred To:  

Questions? Comments? Contact Laura Gopaul